Wind asset operations
Every turbine watched. Every block scheduled.
Windwarden Services runs SCADA monitoring, a 24×7 Remote Operation Center and SLDC scheduling for wind farm owners and IPPs, so your fleet stays visible, available and grid-compliant.
Turbine controller
PLC, converter and met-mast signals read at source.
Site SCADA
Local historian, alarms and a gateway to the cloud.
Windwarden Services ROC
Operators monitor, diagnose and dispatch around the clock.
State SLDC
Schedules, real-time telemetry and grid instructions.
Services
Windwarden Services offerings
Most wind sites run three disconnected systems: a SCADA vendor, a monitoring contractor and a scheduling consultant. Windwarden Services runs all three on one data model, so an alarm at the nacelle and a deviation at the SLDC are traced in the same place.
Layer 1 · Field and SCADA
The fleet on one screen
Select a turbine to see its live signals. The power curve plots each machine against its expected output, so an underperformer stands out before it shows up in a monthly report.
A-01
Running- Active power
- –
- Wind speed
- –
- Rotor speed
- –
- Gearbox oil
- –
- Yaw angle
- –
- Vs power curve
- –
Supported Turbine & Controller Makes
Layer 2 · Remote Operation Center
Operators on watch, around the clock
Every site streams into the ROC. Operators work a single alarm queue ordered by severity, run remote resets where it is safe, and send a technician when it is not. Every action is logged against the turbine.
Layer 3 · State Load Despatch Centre
Scheduled to the block
The grid settles in 96 time blocks of 15 minutes. Windwarden Services prepares the forecast, submits schedules and revisions, streams telemetry and tracks deviation block by block. Requirements differ by state, so each site is configured to its own SLDC, Grid Code and regulator.
Forecast and schedule
Day-ahead schedule plus intra-day revisions as wind conditions shift.
Real-time telemetry
Plant data delivered to the SLDC through the protocol and gateway it specifies, such as IEC 60870-5-104 or ICCP.
Deviation control
Actual against schedule in every block, with early warning before a block drifts out of band.
Instructions and reports
Curtailment instructions relayed to site and logged, with reports ready for audit and settlement checks.
- Block
- –
- Time
- –
- Forecast
- –
- Schedule
- –
- Actual
- –
- Deviation
- –
Sample day with simulated values. Tolerance bands and settlement rules are set by each state's regulator and are configured per site.
Onboarding
From site audit to steady operations
A new site goes through the same four stages. Existing SCADA and contracts stay in place until the ROC is proven.
Audit and data mapping
We review turbines, SCADA, communications and the SLDC requirements that apply to your site.
Integration
Gateways and tags connected, data quality checked, dashboards tuned to your fleet.
Parallel run
The ROC monitors alongside your current setup while schedules and telemetry are tested with the SLDC.
Go live
ROC takes the watch. Monthly reviews track availability, deviation and loss.
Contact
Put a ROC on your wind farm
Tell us about the site and we will respond with an integration plan and a scope for monitoring and scheduling.
Windwarden Services